Theory of Operation Ver. 1.0 Jul. 2009
13.3.10

Transfer belt life detection

• The life counter of the transfer belt controls detection of life of the image transfer belt unit.
• The counter value is recorded in the service EEPROM board of the machine.
Controlled item
Printed page count
Transfer belt rotation time
*1: M represents a code that denotes the image transfer belt unit rotation time.
A. Printed counter life determination
• Each of the printed counter and the transfer belt rotation time counter has its own thresh-
old value to determine its own life. If the printed counter reaches the threshold, the
machine determines that the image transfer belt unit has reached a new state.
Image guaranteed range
Image transfer belt unit
(new article)
(1) Image transfer belt unit printed counter life criteria
State
Normal
Normal
(print enabled: within image guaranteed range)
Reaching life display
Reaching life
(print enabled: outside image guaranteed range)
Life stop
Life stop display (print prohibited)
13. 1ST IMAGE TRANSFER SECTION
Counting unit
Count
*1
M
Reaching life display
(reaching life threshold value)
Outside image
guaranteed range
Display
Life stop display
(life stop threshold value)
Image transfer belt unit
(life end)
A0EDT2C023DA
Criteria
Less than life threshold
Equal to or more than life threshold
and less than life stop threshold
Equal to or more than life stop
threshold
127