Theory of Operation Ver. 1.0 Jul. 2009
F. Temperature control during low power mode
• To reduce power consumption, temperature control is provided with a fusing temperature
lower than a predetermined one that is used in the temperature control during stand-by.
• The temperature control during low power mode ensures that the temperature can be
restored to the print-enable level within 30 sec. max.
G. Temperature control during sleep mode
• To reduce power consumption during the sleep mode, power to the fusing heater lamp is
shut down to stop heating the fusing belt and pressure roller.
• Since the temperature control during sleep mode involves no heating, the temperatures
of the fusing belt and pressure roller can be reduced down to room temperature. Accord-
ingly, time may be required as much as the warm-up time before the print-enable level is
reached.
20. FUSING SECTION
223