11. DEVELOPING SECTION
11.3.8

Developing unit detection

• The developing unit of each color of toner is provided with a TCR sensor board. The
board detects different states of the corresponding developing unit.
Unit mounting
New article
detection
detection
control
control
A. Unit mounting detection
• The TCR sensor board detects the mounting condition of the developing unit.
• When developing unit is detected in the mounted condition, control now proceeds to the
"new article detection control".
(1) Detection timing
• The unit mounting detection control is performed under any of the following conditions:
"The power switch is turned ON (with the front door and right door are closed)"
"The front door or right door is opened and closed with the power switch in ON position"
(2) Operation when it is detected that no units are mounted
• The message "Developing Unit Installation Error" appears on the control panel and the
machine prohibits initiation of any new print cycle.
• The message "Developing Unit Installation Error" disappears as soon as a developing
unit is mounted.
84
Theory of Operation Ver. 1.0 Jul. 2009
TCR sensor
Image
automatic
adjustment
stabilization
control
control
(calibration)
Life counter
zero reset
Life detection
(only for a
control
new article)
A0EDT2C004DA