5.3 – ELEcTRIcAL cONNEcTION
WARNING
before connecting the refrigerator, make sure that there is an efficient earthing
system, compliant with European Standards (EN).
WARNING
before making any wiring connection, make sure that the main
breaker is off (OFF) (Fig. 5.1.4).
PLEASE NOTE:
For correct connection see the attached wiring diagram accompanying this
manual.
5.3.1 - INSTRUcTIONS FOR cONNEcTION TO MAINS POWER (Ac and DW- IM
models only)
Prepare the v AC power supply line using a three-pole cable with a minimum section per
conductor of 1 sq mm, suitable insulation for the intended use and environment and compliant
with the standards in force.
Make sure there is an access point to mains electricity near to the appliance and that the mains
system has been fitted with a differential thermomagnetic omnipolar switch (6 A). The mains
voltage needs to be the same as that listed on the rating label inside the appliance. The
refrigerator has a power cord, provided with or without plug: if there is a plug, connect the cap
to a socket compliant with the current standards and in a place that is easily accessible; if there
is no mains connection, fit a bipolar switch (compliant with standards) with a distance between
switch contacts of no less than 3mm (accessible). This installation and electrical connection
must be performed to comply with standards by a specialised technician.
At the end of the installation, check the continuity of the earthing circuit and carry out all of the
electrical safety tests envisaged in current standards.
Protect the power cords and secure them in place to prevent anything from pulling them out of
connections or allowing them to come into contact with temperatures over 50°C or sharp parts.
If the power cord is damaged, it must be replaced by the manufacturer or the manufacturer's
technical assistance service or in any case, by a person with a similar qualification so as to prevent
any risk.
WARNING
The installation of power lines must be carried out by qualified
persons who can check the system's compliance with
current regulations and issue the relevant conformity certification.
The manufacturer hereby refuses to accept any liability for damages to people
or property arising from the failure to respect this regulation.