6 Electrical connection

It is recommended to connect the 12Vdc or 24Vdc power supply line directly to
the battery by following the corresponding instructions of the supplied control
unit (see Attachment 2).
Prepare the power supply line in AC (in case of a two-way system) using a
three-core cable with a minimum cross-section for a 1 mmq (17AWG)
conductor and insulation suitable for the modes of use and the environment
and compliant with the regulations in force.
Make the connection to the AC power line by means of a plug connection with
an adequate flow rate compliant with current regulations or prepare an
omnipolar magnetothermal differential switch with a capacity of 6 amps and
with contact opening of at least 3 mm (0,12 in) or nevertheless in compliance
with current regulations.
Once installation has been completed, check the continuity of the earth circuit
and carry out all the electrical safety tests provided for by current regulations.
Protect and lock the cables in order to prevent accidental pulling of the cable
from disconnecting it from the connections or coming into contact with hot parts
with a temperature above 50°C (122°F)or with sharp parts.
It is recommended that the installation of the power supply lines is carried out
by qualified personnel who will check the compliance of the unit with the
regulations in force and issue the relative certifications of conformity.