Electrical Connection - Vitrifrigo SLIM 150 Installation Use And Assistance Manual

Table of Contents

Advertisement

Available languages

Available languages

10. Electrical Connection

Prepare the AC supply line using conductor cable of mimimum1mm
section and proper insulation adequate to the operating mode and environment and
in compliance with the applicable regulations.
Make sure that there is available an access point to the power supply near the unit
and that the system is equipped with a 6-pole omnipolar differential magnetic circuit
breaker.
The main voltage must correspond to the voltage indicated on the identification label
located inside the appliance. If the appliance is equipped with a plug-in power cord,
apply a two-pole switch to a standard with a minimum contact opening distance of 3
mm.
This installation and electrical connection must perform in accordance with the
regulations by a qualified technician.
Connect the DC power supply to 12V or 24V directly to the battery according to the
following instructions.
Standard battery protection settings.
12V cut-out [V]
10.4
Cable size: Battery and electronics connection.
2
Section [mm
]
2.5
4
6
10
Protect
the
DC
power
Provide a fuse close to the positive battery pole and a 15A fuse for 12 VDC power
supply and 7.5A for 24 VDC power supply.
12V cut-in [V]
24V cut-out [V]
11.7
Max line length 12V [m]
2.5
4
6
10
line
with
a
suitable
30
2
(AWG16) cross-
24V cut-in [V]
22.8
24.2
Max line length 24V [m]
5
8
12
20
min.
20A
circuit
EN
breaker.

Hide quick links: