2. Open the front bezel on both servers.
See "To Open The Front Bezel" on page 22.
3. Remove the cable ties that secure the system configuration cards, and remove the
cards.
4. Insert the system configuration card from the old server into the new one.
5. Replace the cable tie on the new system.
6. Power on the new system.
Tie wrap
System configuration card
FIGURE 2-3
Caution – Never remove the system configuration card while the server is booting
or running the Solaris operating environment. Either remove power from the server,
or put it into Standby mode, before removing or inserting the system configuration
card.
Caution – Do not handle the system configuration card unless you need to transfer
it to another system. If you need to handle it for this reason, avoid contact with the
gold terminals on the underside of the card.
26
Sun Fire V210 and V240 Servers Administration Guide • April 2003
Inserting a System Configuration Card (Sun Fire V210 Server Shown)