Datamax I-class Maintenance Manual page 16

Hide thumbs Also See for I-class:
Table of Contents

Advertisement

Step
Action
Press the
increment the Gain Number
then press the
record the resulting TOF Value.
11
Repeat this step for each of the
remaining Gain Numbers (01-
31).
From the collected data, where
both the values are above 20,
subtract the Label Value from
the corresponding TOF Value to
12
find the Difference Value.
Note the Gain Number of the
largest Difference Value.
(continued)
Adjustments and Maintenance
Sampling Table
Gain
Label
Number
Value
00
255
01
251
02
241
...
...
31
112
Displayed Message
GAIN TRAN
Key to
*31
Key and
Or, for reflective media:
GAIN REFL
*31
GAIN TRAN
*31
Or, for reflective media:
GAIN REFL
*31
Sampling Table
Gain
Label
Number
Value
00
255
01
251
02
241
03
231
04
219
05
212
06
200
07
189
08
178
09
167
10
156
...
...
31
116
TOF
Difference
Value
Value
254
<yyy>
<0 - 31>
<yyy>
<0 - 31>
<yyy>
<0 - 31>
<yyy>
<0 - 31>
TOF
Difference
Value
Value
254
1
240
11
213
28
182
49
150
69
119
93
88
112
58
131
32
146
19
N/A
17
N/A
...
...
14
N/A
2-6
Comment
For example in the table
below, Gain Number 08 is
chosen because it has the
highest Difference Value
(146) where both the Label
and the TOF Values are
above 20.

Advertisement