Installing the System
Cabling and Powering On the Server

Installing The Line Cord Anchor (rack mounted servers)

The line cord anchor is attached to the rear of the server when rack mounted. It provides a method to secure
the line cords to the server preventing accidental removal of the cords from the server.
Four Cell Server Installation (rp8400, rp8420, rp8440, rx8620, rx8640)
There are pre-drilled holes and pre-installed captive nuts in the server chassis.
To install the line cord anchor
1. Align the line cord anchor thumbscrews with the corresponding captive nuts at the rear of the chassis.
Refer to Figure 2-28, "Four Cell Line Cord Anchor (rp8400, rp8420, rp8440, rx8620, rx8640),"
Figure 2-28
Four Cell Line Cord Anchor (rp8400, rp8420, rp8440, rx8620, rx8640)
2. Tighten the captive thumbscrews to secure the line cord anchor to the chassis.
3. Weave the power cables through the line cord anchor. Leave enough slack that the plugs can be
disconnected from the receptacles without removing the cords from the line cord anchor