2.2 Installing the appliance

• Install on a stable, solid surface (concrete slab for example) which is level,
• Protect from risks of flooding due to condensates from the appliance when it is running (see §2.3).
The anti-vibration blocs are fitted under the base of the heat pump.
The heat pump can be fixed to the ground using the brackets at the base of the unit (attachments not included).
A diagram for drilling is featured on the back of the packing box.

2.3 Hydraulic connections

• The connection include a Ø 50 PVC rigid pipe, from a by-pass, on the swimming pool filtration circuit, after the filter and
before any water treatment unit.
• Installing a by-pass is mandatory and facilitates operations on the appliance.
• Adjust the water flow using valve V1, and leave valves V4 and V5 open.
• Make sure the hydraulic fittings are correctly tightened and that there are no leaks.
Disposing of condensation:
Warning: your device can produce several litres of water per day. It is strongly recommended to guide the flow to
drains.
• Connect a Ø18 interior pipe (not supplied), to the grooved end-piece mounted on the base of the appliance,
• Outlet: to the back or on the side :

2.4 Electrical connections

2.4.1 Voltage and protection
• The electrical supply to the heat pump must include a protection and circuit-breaker device (not supplied) complying
with the standards and regulations in force in the country,
• Additional protection may be required during installation to protect against overvoltage category II,
• The device is designed for connection to a general power grid with TT and TN.S grounding systems,
• Electrical protection: circuit-breaker (curve D) or fuse (Am) (see § 2.4.3 for ratings), and with a 30 mA dedicated
differential trip switch (circuit-breaker or switch).
H0439100.B - EN - 2014-09
Fixing holes
V1-2-3 : by-pass valves
V4 : water intake valve
V5 : water output valve
* minimum distance
Z300
Test pressure
bar
Service pressure
bar
Load loss
mCE 1,4
Mean water
m³/h
flowrate
Follow the hydraulic connection direction
(see § «Dimensions» in the appendix).
M5
T5
MD8
M4
M7
MD5
TD8
TD5
3
1,5
1,5
1,5
1,1
4
5
6
6,5
4