Location and mounting requirements

The SmartNode 4300 is intended to be placed on a desktop or similar sturdy, flat surface that offers easy access
to the cables or be installed in a standard 19-inch rack chassis. Allow sufficient space at the rear of the chassis
for cable connections. Additionally, you should consider the need to access the unit for future upgrades
and maintenance.
Airflow requirements – To ensure proper airflow through the SmartNode, follow these recommendations
when you are installing your unit:
– If placed on a desktop, leave 7.62 cm (3 inches) of minimum clearance on both the left and right sides of
the unit.
– If mounted in a rack, leave a one-rack unit (1U) of minimum clearance above and below the unit for
proper airflow.
Note
The SmartNode 4900 model is available for racks that require tighter spacing
requirements than what the SN4300 model allows for minimum clearance.
This completes the planning phase for installation. The next section begins the installation procedures.

Installing the IpChannel Bank

Unpacking the Model SN4300 series IpChannel Bank

Inspect the shipping carton for external damage. Note any damage before removing the container contents.
Report any equipment damage to the shipping carrier immediately for claim purposes. Save all packing mate-
rial in case you need to return an item to the factory for servicing.
The IpChannel Bank comes with the following items:
Model SN4300 Series IpChannel Bank Quick Start Guide
Model SN4300 Series IpChannel Bank
An RJ-45-to-RJ-45 cable for use with the console and Ethernet ports
A DB-9-to-RJ-45 (EIA-561) adapter for connecting a PC's serial port to the IpChannel Bank console port
Note
Power cables are shipped separately from the Model SN4300 Series IpChan-
nel Bank
Note
Contact Patton Electronics for the proper RJ-21X cable for the FSX ports

IpChannel Bank chassis installation

Do the following:
1. If you have not done so already, remove the IpChannel Bank from its shipping container.
2. If you are installing the IpChannel Bank in a 19-inch rack, go to step 4. Otherwise, place the IpChannel
Bank at the desired location.
3. Go to section
"Connecting cables"
4. Install the rack mounting ears onto the IpChannel Bank using the mounting hardware provided.

Installing the IpChannel Bank

on page 28
3 • Hardware installation
27