TS-2030EN/TS-2076EN Series Progressive Scan Cameras
You can connect up to two light sensors. If two IP addresses and port numbers are identical, then the
EN camera tries to connect only a single light sensor.
Set the ADR Control register from "Manual" to "ADR Control (Using the Light Sensor)." This will
activate the connection to the light sensor. If the connection is successful, you should see a live data
change in the ADR Debug side A/B registers. Also, you should see what camera parameters ADR
decides to set. In the above example, ADR sets to exposure time 4H (Dial 4 = 4H), Gain=255(max),
Vtop=0, and Vbot=0. If there is a connection error, then these register values will all remain zero.
Also, check the "Error Status" register. If there is a connection error, LS1_ERR or LS2_ERR is set. If a
light sensor is not required for your application, set the "Camera ADR Control" register to "Manual."