D16 and S128P Sub-Zones W/O Volume Controls

ELAN special application
Prerequisites: Factory Default the amp and set to ELAN Mode.
Channel Range: Set to 1 to 16
Input Select Menu:
Channel 1 with Input set to 1 Direct
Channel 2 with Input set to 2 Direct
Channel 3 with Input set to 3 Direct
Channel 4 with Input set to 4 Direct
See:
Restore Defaults on page 29, Operating Mode Menu on page 23
Channel Range Menu on page 34, Input Select Menu on page 17
Appendix A: IR / VIA!NET Command Set
Instead of using volume controls to have independent control of the volume in a zone and
sub zone, control the Sub-Zone channels of the D16 using IR Commands. Route the
VARIABLE out of Zone 1 of the S128P to audio inputs 1 and 2 and route the FIXED out of
Zone 1 of the S128P to audio inputs 3 and 4.
The S128P increases or decreases the volume level for channels 1 and 2 Main Zone.
To control the Sub Zone speakers that are connected to channels 3 and 4, send IR
Commands to the D16. These commands can be programmed on a different ELAN control
located in the Sub Zone or from the same control located in the Main Zone.
Remember to connect the IR input to the D16.
(Wiring example on next page.)