Stereo Zones w/ Mono Sub-Zones
Use the Loop Out Jacks and an RCA 'Y' cable to create Mono sub-zones with Stereo zones. This application is per-
fect for large rooms with smaller rooms attached such as a Master Bedroom/Master Bath or Kitchen/Laundry Room.
D1650
Digital
Power Amplifier
© ELAN Home Systems, Inc. 2004 • All rights reserved. 7/04
ELAN Multi-Room Controller
ZONE OUTPUTS
Stereo Zone w/ Mono Sub-Zone
Zone 1 Output to Line Inputs 1 & 2
Line Outputs 1 & 2 to RCA 'Y' Cable
RCA 'Y' Cable to Line Input 3
All Speakers Volume Ramps Up/Down Together
Speaker Outputs Coincide w/ Line Inputs