Balance charging of lithium battery

NiMH Sensitivity
D.Peak
Default
-
-
+
DEC
INC
DEC
Batt type
Start
'>3 seconds'
Stop
Enter
NiMH Sensitivity
D.Peak
Default
Start
Enter
NiMH Sensitivity
D.Peak
Default
Number
Battery
Charging
of
voltage
time
cells
Charging
current
Charging lithium battery in the balance mode
This function is for balancing the voltage of Lithium-polymer battery cells while charging. In the
balance mode, the battery needs to have a balance lead to connect to the individual balance port
at the right side of the charger. And you need to connect the battery's power lead to the output of
charger.
Charging in this mode is different from the normal modes, because the built-in processor
monitors voltage of individual cell and control input current fed into each cell to equalized voltage
of individual cell.
BALANCE CHARGING OF LITHIUM BATTERY
The left side of the first line shows the type of battery you choose.
The value on the left of the second line of the charger is current
u s e r s e t , A f t e r s e t t i n g t h e c u r r e n t a n d v o l t a g e , p r e s s
START/ENTER key for more than 3 seconds to start the
+
process.(charge current: 0.1-5.0A, voltage: 3.7-22.2V).
INC
This displays the number of cells you set up and the processor
detects. "R" shows the number of cells detected by the charger
and "S" is the number of cells set by you at the previous screen. If
both numbers are identical you can start charging by press
START/ENTER button. If not, press BATT TYPE/STOP button to
go back to previous screen to carefully check the number of cells
of the battery pack before going ahead.
This screen shows the real-time status during charge process.
Press BATT TYPE/STOP key once to stop the charge process.
Charged
capacity
17