Congratulations on your choice of SKYRC B6 V2 DC Balance
01
Charger/Discharger. This unit is simple to use, but the operation of
03
a sophisticated automatic charger such as SKYRC B6 V2 does
05
require some knowledge on the part of the user. These operating
08
instructions are designed to ensure that you quickly become
10
familiar with its functions. It is therefore important that you read
11
right through the Operating Instructions, Warning and Safety
13
Notes before you attempt to use your new charger for the first
14
time. We hope you have many years of pleasure and success with
17
your new battery charger.
22
26
SkyRC B6 V2 is a high-performance, micro processor control
28
charge/discharge with battery management suitable for use with
29
all current battery types(LiPo/LiFe/Li-Ion/LiHV/NiMH/NiCd/Pb)
31
batteries.The charger deliver dedicated 60W integrated power
33
and can fill battery at up to 6A. Except SkyRC normal charging
34
programs, it is versatile with the addition of AGM and Cold modes
35
for Lead Acid(Pb) battery.
36
37
This charger can be powered by 11-18V DC, it is able to power
38
DC equipment such as LED pit light, motor checker, etc.
39
Please BE SURE to read these INSTRUCTIONS, WARNING and
40
SAFETY NOTES before you use the charger for the first time.It
41
can be dangerous to mis-handle batteries and battery chargers,
as there is always a risk of batteries catching fire and exploding.
Mishandling batteries and battery
chargers is extremely dangerous,
which may cause fire and explosion.
B6 V2
Introduction
01 ·

Advertisement

Table of Contents
loading

Summary of Contents for Skyrc IMAX B6 V2

  • Page 1: Table Of Contents

    System Setting batteries.The charger deliver dedicated 60W integrated power Battery Voltage Meter and can fill battery at up to 6A. Except SkyRC normal charging Battery Resistance Meter programs, it is versatile with the addition of AGM and Cold modes Warning and Error Message for Lead Acid(Pb) battery.
  • Page 2: Introduction

    Resume or Start LCD Display Voltage Calibration (for expert user only) Charge Processes SkyRC B6 V2 allows you to calibrate the voltage directly on the DC Input device with a 6S LiPo battery. (For more information please contact us at support@skyrc.cn)
  • Page 3: Warning And Safety Notes

    Special Features Warning and Safety Notes Storage Mode of Lithium Battery These warnings and safety notes are particularly important. Please follow the instructions for maximum safety; “STORAGE” has the capacity to control the final battery voltage, otherwise the charger and the battery can be damaged or at which is necessary and helpful for a rarely used battery.
  • Page 4 Warning and Safety Notes Warning and Safety Notes Never attempt to charge or discharge the following types Connect the battery to the terminal of the charger: red is positive of batteries. and black is negative. Due to the difference between resistance of cable and connector, the charger can not detect resistance of the A battery pack which consists of different types of cells (including battery pack, the essential requirement for the charger to work...
  • Page 5: Program Flow Chart

    Program Flow Chart Program Flow Chart · 08 B6 V2 B6 V2 09 ·...
  • Page 6: Explanation Of Buttons

    Explanation of Buttons Power and Battery Connection 1. Connecting to power source 12V DC Battery / Power Adapter Output DC 11-18V BATT PROG / STOP Button: It is used to stop the progress or go back to previous step/screen DEC Button: It is used to go through the menus and decrease the parameter value INC Button: It is used to go through the menus and increase the parameter value...
  • Page 7: Power And Battery Connection

    Power and Battery Connection Charge Operation 2. Connecting the battery Charging Program TO AVOID SHORT CIRCUITS, ALWAYS CONNECT Depends on different battery type, the operation programs are different. THE CHARGE LEADS TO THE CHARGER FIRST, Batt Operation Description Type Program AND THEN TO THE BATTERY.
  • Page 8 Lithium Battery Program Lithium Battery Program (LiPo/LiFe/Lilon/LiHV) (LiPo/LiFe/Lilon/LiHV) A memory profile is available for setting and storing pertinent BATTERY CHECK The charger is detecting the battery cell. information for up to 10 different program sets. Once a battery ....program is stored into memory, it will be retained until changed R shows the number of cells detected by the again manually.
  • Page 9: Lithium Battery Program (Lipo/Life/Lilon/Lihv)

    Lithium Battery Program NiMH/NiCd Battery Program (LiPo/LiFe/Lilon/LiHV) NiMH/NiCd: VARIOUS INFORMATION DURING THE PROCESS This program is only suitable for charging/discharging NiMH/NiCd Press INC or DEC during the charging or discharging process to batteries. The B6 V2 offers the following NiMH/NiCd charge modes: view further pertinent information on the LCD screen.
  • Page 10 NiMH/NiCd Battery Program NiMH/NiCd Battery Program NiMH/NiCd Discharge Mode: NiMH/NiCd Re-Peak Mode: Applicable to NiMH and NiCD batteries only, in re-peak mode the After selecting the correct battery type, use NiMH DISCHARGE charger can peak- charge the battery once, twice, or three times in a the INC or DEC button to select the 1.3A CUT: 5.10V...
  • Page 11 NiMH/NiCd Battery Program NiMH/NiCd Battery Program NiMH/NiCd Cycle Mode: see “D>C“ or “C>D“. This will indicate which cycling order you have chosen. The B6 V2 makes cycling of NiMH/NiCd batteries easy. The process of Either “D“ or “C“ will be flashing. This flashing discharging and recharging (cycling) can be performed automatically indicates which part of the cycle is currently with one simple step and will improve the performance of NiMH/NiCd...
  • Page 12: Pb Lead-Acid Battery Program

    Pb Lead-acid Battery Program Pb Lead-acid Battery Program Pb AGM Mode: Pb Lead-Acid Battery Program After selecting the correct battery type, use the INC or DEC button to Pb (Lead-Acid): change it to the “AGM CHARGE“ mode. This program is only suitable for charging Press the START button and the amp rate value will begin flashing.
  • Page 13 Pb Lead-acid Battery Program Pb Lead-acid Battery Program Pb Cold Mode: Once discharging has commenced, the DONE 13.62V charger will display the following real-time DCHG 00106mAh Press the START button again and the Pb COLD CHG nominal battery pack voltage will begin information: battery type, cell count, discharging 1.5A 12.0V(6P) flashing.
  • Page 14: Dji Battery Program

    DJI Battery Program DJI Battery Program This program is only suitable for charging/ discharging DJI Mavic Once charging has commenced, the charger 50% 10.20V and TB4X battery, B6V2 offers two operation modes: charge and will display the following real-time information: C 2.0A 00301mAh storage.
  • Page 15: Dc/Dc Converter

    DC / DC Converter Battery Memory Set and Call Out B6 V2 charger is integrated with a DC/DC converter. A DC/DC The charger can store up to 10 different charge/discharge profiles for converter is an electronic circuit that converts a source of direct your convenience, and the stored profiles can be recalled quickly current (DC) from one voltage level to another.
  • Page 16: System Setting

    Battery Memory Set and Call Out System Setting It will be operated with the default value of the essential user settings T V C = Y O U R R I S K Set the terminal voltage(4.18-4.25V). when it is powered on for the first time.The screen displays the 4 .
  • Page 17: Battery Voltage Meter

    System Setting Battery Voltage Meter The user can check battery's total voltage, the highest voltage, the ITEM SELECTION DESCRIPTION lowest voltage and each cell's voltage. This program is for NiMH/NiCd Please connect the battery to the charger main battery lead to N i M H S e n s i t i v i t y battery only.
  • Page 18: Battery Resistance Meter

    Battery Resistance Meter Warning and Error Message In case of an error the screen will display the cause of error and emit The user can check battery's total resistance, the highest resistance, an audible sound. the lowest resistance and each cell's resistance. Please connect the battery to the charger main battery lead to battery Incorrect polarity connected.
  • Page 19: The Set Contains

    The Set Contains Specification DC Input Voltage:11-18V THE SET CONTAINS Display Type: 2x16 LCD Display Backlight: Blue 1. SKYRC B6 V2 Charger Case Material: Aluminium Controls: Four Buttons Case Size: 115x84x31mm Weight: 238g 2. DC Input Cable External Port: 1-6S Balance Socket-XH, Temperature Probe Socket, 3.
  • Page 20: Conformity Declaration

    Conformity Declaration Regulatory Information SkyRC B6 V2 satisfy all relevant and mandatory EC directives and FCC FCC Note: Part 15 Subpart B. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:...
  • Page 21: Commonly Used Terms

    This charger is designed and approved exclusively for use with the types of (capacity limit) is reached. The charge process switches from a high battery stated in this Instruction Manual. SkyRC accepts no liability of any current to a low maintenance rate (trickle charge) at this point. From kind if the charger is used for any purpose other than that stated.