SPECIAL FEATURES
Maximum safety
Delta-peak sensitivity: The automatic charge termination program based on the principle of the
Delta-peak voltage detection. When the battery's voltage exceeds the threshold, the process
will be terminated automatically.
Automatic charging current limit
You can set up the upper limit of the charging current when charging your NiCd or NiMH battery;
it is useful for the NiMH battery of low impedance and capacity in the 'AUTO' charging mode.
Capacity limit
The charging capacity is always calculated as the charging current multiplied by time. If the
charging capacity exceeds the limit, the process will be terminated automatically when you set
the maximum value.
Temperature threshold*
The battery's internal chemical reaction will cause the temperature of the battery to rise. If the
temperature limit is reached, the process will be terminated.
* This function is available by connecting optional temperature probe, which is not included in
the package.
Processing time limit:
You can also limit the maximum process time to avoid any possible defect.
Data store/load
The maximum five batteries'data can be stored for users'convenience. You can keep the data
pertaining to program setting of the battery of continuous charging or discharging. Users can
call out these data at any time without any special program setting.
Cyclic charging/discharging
1 to 5 cyclic and continuous process of charge>discharge or discharge>charge is operable for
battery refreshing and balancing to stimulate the battery's activity.