Draining Procedures (Pre-Filter)
1. Place 0.5 liters (0.5 US qt) or larger capacity container
under drain plug (5) to collect the drained water.
2. Loosen plug (4) on the top of the fuel pre-filter.
3. Rotate drain plug (5) on the bottom of the pre-filter
counterclockwise. Drain the water accumulated in the
filter until the float goes to the bottom of case.
4. After draining water, securely tighten drain plug (5) and
plug (4).
5. Start the engine. Check drain plug (5) and plug (4) for
fuel leaks.
IMPORTANT: After draining water mixed in fuel, bleed air
from the fuel supply system.