PILOT CONTROL SHUT-OFF LEVER
Pilot control shut-off lever (1) functions to prevent the
machine from being mistakenly operated when the operator is
getting on or off the machine.
d
WARNING:
• Pilot control will not be shut-off unless pilot con-
trol shut-off lever (1) is completely pulled-up to the
LOCK position.
• Before leaving the operator's seat, always stop the
engine and pull pilot control shut-off lever (1) up
to the LOCK position.
• Also, pull pilot control shut-off lever (1) up to the
LOCK position when transporting the machine or
when the day's work is complete.
• Confirm that pilot control shut-off lever (1) is in the
LOCK position before starting the engine.
ENGINE STOP SWITCH
If the engine does not stop even if the key switch is turned OFF
due to failure of the machine, move switch (2) located at the
front-left side off the seat stand downward to stop the engine.
After operating switch (2), be sure to return switch (2) back to
the upward position.
OPERATOR'S STATION
1-62
1
LOCK Position
1
UNLOCK Position
2
M1U1-01-025
M1U1-01-024
M1U1-01-029