C. TRANSMISSION
1

Pump Transmission

Check Oil Level --- every 250 hours
ZX650LC
, 850LC
-3
-3
1. Park the machine on a level surface.
2. Lower the bucket to the ground.
3. Turn the auto-idle switch off.
IMPORTANT: The turbocharger may be damaged if the
engine is not properly shut down.
4. Run the engine at slow idle speed without load for five
minutes.
5. Stop the engine. Remove the key from the key switch.
6. Pull the pilot control shut-off lever to the LOCK position.
d
WARNING: Engine oil may be hot just after operation.
Wait for engine oil to cool before starting work.
7. Remove dipstick (1). Oil must be within the specified
range.
8. If necessary, remove socket (5) of air breather (4) and add
oil from supply plug (2). (See engine oil chart)
9. Recheck oil level.
Change Engine Oil --- every 1000 hours
Clean Air Breather --- every 1000 hours
1. Park the machine on a level surface.
2. Lower the bucket to the ground.
3. Turn the auto-idle switch off.
IMPORTANT: The turbocharger may be damaged if the
engine is not properly shut down.
4. Run the engine at slow idle speed without load for five
minutes.
5. Stop the engine. Remove the key from the key switch.
6. Pull the pilot control shut-off lever to the LOCK position.
d
WARNING: Gear oil may be hot just after operation.
Wait for gear oil to cool before starting work.
7. Remove drain plug (3) and open drain cock (6) to drain
oil.
8. Reinstall drain plug (3) and close drain cock (6).
MAINTENANCE
5
6
Specified Range
7-44
4
1
M104-07-021
2
M1JB-07-035
3
M1JB-07-044
1
M16J-07-048