NOTE: Lifting yokes must be in the forward position or
highest point of the slot.
23. Slowly move the counterweight pilot valve lever UP
until counterweight bottom bosses (21) move away
from machine mainframe (20) approximately 2 to 5 mm
(0.1 to 0.2 in) (A). This will ensure that the weight of the
counterweight is on the lift cylinder.
IMPORTANT: When the threads of tie bolt (11) disengage
from nut (12), nut (12) and nut spacer may
drop to the ground. Stay clear from under
the machine when removing bolts (11).
24. To avoid binding, loosen bolts (11) by alternately turning
each bolt one turn at-a-time.
f
NOTE: It is not necessary to remove bolts (11) from the
counterweight/frame holes. It is enough nuts (12) are
dropped down. The bolts (11) will be removed from
frame holes when the counterweight is lowered by
the lift cylinder.
25. Remove bolt (18), lock plates (19), boss plate (22) and
shim (23) from each counterweight boss. To avoid
binding, alternately loosen left hand and right hand bolt
(18) 2 or 3 turns at-a-time.