Manual Lubrication
Perform manual lubrication using a manual lubricator.
Manually lubricate the bucket joint pins swing bearing,
swing gears in addition use manual lubrication system
when adjusting the track sag or in case the auto-lubrication
system fails.
IMPORTANT: The system will not operate unless grease
pump switch (1) and switch (10) are ON,
Check if grease pump switch (1) and switch
(10) are ON in case the system does not
operate.
1. Turn grease pump switch (1) ON.
2. Move lubrication control valve lever (2) in the lubricator
box to the MANUAL position.
3. Turn lubrication mode switch (3) on the switch panel
under the left armrest to the MANUAL position. Auto-
lubrication alarm on the monitor panel comes ON at this
time.
f
NOTE: A lit the auto-lubrication alarm does not mean that
the auto-lubrication system has become inoperable.
This is a normal operation at this time.
4. Using the lubricator and grease gun, add grease to the
respective greasing points.
IMPORTANT: After completing lubrication release the
remaining pressure to protect the grease
pump from being damaged