Alarm Setting
The Alarm Setting Menu allows you to edit
alarm related configuration.
Please refer to below for the configurable
settings:
-
Exit time: Time period given after initiating
the arming process. During this time, no
sensors will trigger the alarm and you can
exit the premises before the system enters
arm mode. Default exit time is 30 seconds.
-
Exit sound: Exit time countdown beep
volume. Default exit sound is Low.
-
Entry time: Time period given after
triggering a device set with Entry attribute.
During this time, the system will need to be
disarmed, or the alarm will be activated.
Default Entry time is 20 seconds.
-
Entry sound: Entry time countdown beep
volume. Default entry sound is Low.
-
Alarm length: The time for the alarm to be
activated for. Default alarm length is 3
minutes (180 seconds).
-
Door Chime Volume: The Door Chime
sound activated by the Control Panel when
a device set with entry attribute is triggered
under Disarm mode. Default door chime is
Disable.
-
Jamming function: Signal interference
detection feature. When RF signal jamming
interference is detected for a continuous 30
seconds, the alarm will be activated. Factory
Default is Disable.
-
High
Temperature
Temperature Sensor required ): When
enabled, if the temperature exceeds this
threshold by 1°C, a SMS alarm report will be
sent to programmed telephone number.
When the temperature drops to 3°C below
the threshold, a SMS report will be sent to
the programmed telephone number to notify
the
recipient
Restoration.
-
Low
Temperature
Temperature Sensor required ): When
enabled, the temperature drops below this
threshold by 1°C, a SMS alarm report will be
sent to programmed telephone number.
When the temperature returns to 3°C above
the threshold, a SMS report will be sent to
the programmed telephone number to notify
the
recipient
Restoration.
Select the option you want to edit, you will
enter the edit screen
16
alarm
(Optional
of
High
Temperature
alarm
(Optional
of
Low
Temperature

Advertisement

loading