Connector
Pin No.
YC14
A1
Connected
A2
to the feed-
A3
shift sole-
A4
noid,
feedshift
A5
switch, eject
A6
switch, cool-
A7
ing fan
motor 3, left
A8
cover 1
A9
switch,
A10
upper/lower
paper feed
A11
clutches,
A12
humidity
sensor and
A13
eject motor
A14
A15
A16
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
Signal
I/O
FSSOL2
O
FSSOL1
O
+24VDR
O
GND
-
FSSW
I
+5VD
O
GND
-
PFS
I
+5VD
O
GND
-
ESW
I
+5VD
O
CFM3
O
GND
-
GND
-
LC1SW
I
PFCL-U
O
+24VDR
O
+24VDR
O
PFCL-L
O
+24VDR
O
RCL
O
+3VD
O
HUMS
I
GND
-
THOUT
I
EM_B
O
EM B
O
EM_A
O
EM A
O
NC
-
NC
-
Voltage
0/24 V DC
FSSOL: On/Off (return)
0/24 V DC
FSSOL: On/Off (activate)
24 V DC
24 V DC power output
-
Ground
0/5 V DC
FSSW: On/Off
5 V DC
5 V DC power output
-
Ground
0/5 V DC
PFS: On/Off
5 V DC
5 V DC power output
-
Ground
0/5 V DC
ESW: On/Off
5 V DC
5 V DC power output
0/24 V DC
CFM3: On/Off
-
Ground
-
Ground
0/5 V DC
LC1SW: On/Off
0/24 V DC
PFCL-U: On/Off
24 V DC
24 V DC power output
24 V DC
24 V DC power output
0/24 V DC
PFCL-L: On/Off
24 V DC
24 V DC power output
0/24 V DC
RCL: On/Off
3.3 V DC
3.3 V DC power output
Analog
HUMS detection voltage signal
-
Ground
Analog
Thermistor detection voltage signal
0/24 V DC (pulse) EM drive control signal
0/24 V DC (pulse) EM drive control signal
0/24 V DC (pulse) EM drive control signal
0/24 V DC (pulse) EM drive control signal
-
Not used
-
Not used
2GZ/2G1-2