Superior DRT2000 Series Installation And Operation Instructions For

Direct-vent gas fireplaces
Hide thumbs Also See for DRT2000 Series:

Advertisement

P/N 900004-00 REV. J 03/2017
Ce manuel est disponible en francais, simplement en
faire la demande. Numéro de la pièce 900004-02.
P900004-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by
a qualifi ed installer, service agency or the gas
supplier.
Installation and Operation Instructions
DRT2000 and DRC2000 Series Direct-Vent Gas Fireplaces
Models
Traditional
C
US
DRT2033TMN
DRT2033TMP
DRT2033TEN
Report No. F13-094
DRT2033TEP
Contemporary
DRC2033TMN
DRC2033TMP
DRC2033TEN
DRC2033TEP
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
DRT2033RMN
DRT2035TMN
DRT2035RMN
DRT2033RMP
DRT2035TMP
DRT2035RMP
DRT2033REN
DRT2035TEN
DRT2035REN
DRT2033REP
DRT2035TEP
DRT2035REP
DRC2033RMN
DRC2035TMN
DRC2035RMN
DRC2033RMP
DRC2035TMP
DRC2035RMP
DRC2035REN
DRC2033REN
DRC2035TEN
DRC2033REP
DRC2035TEP
DRC2035REP
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides infl ammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifi é
ou par le fournisseur de gaz.
DRT2040TMN
DRT2045DMN
DRT2040RMN
DRT2040TMP
DRT2045DMP
DRT2040RMP
DRT2040TEN
DRT2040REN
DRT2045DEN
DRT2040TEP
DRT2045DEP
DRT2040REP
DRC2040TMN
DRC2040RMN
DRC2045DMN
DRC2040TMP
DRC2040RMP
DRC2045DMP
DRC2040TEN
DRC2040REN
DRC2045DEN
DRC2040TEP
DRC2040REP
DRC2045DEP

Advertisement

Table of Contents
loading

Summary of Contents for Superior DRT2000 Series

  • Page 1 Installation and Operation Instructions DRT2000 and DRC2000 Series Direct-Vent Gas Fireplaces P/N 900004-00 REV. J 03/2017 Models Ce manuel est disponible en francais, simplement en Traditional faire la demande. Numéro de la pièce 900004-02. DRT2033TMN DRT2033RMN DRT2035TMN DRT2035RMN DRT2040TMN DRT2045DMN DRT2040RMN DRT2033TMP DRT2033RMP...
  • Page 2: General Information

    Innovative Hearth Products General Information DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 SAFETY AND YOUR FIREPLACE See attached color fl yer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.
  • Page 3 Innovative Hearth Products General Information DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fi replace get chimenea IHP se ponen foyer IHP deviennent EXTRÊMEMENT CHAUDES !
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Traditional Fireplace Contemporary Fireplace THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
  • Page 5: Important Safety Information

    Innovative Hearth Products General Information DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 IMPORTANT SAFETY INFORMATION Important Safety Informa- L’information de sûreté Información importante de tion importante seguridad 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked si le panneau frontal en verre n’est pas en frente de vidrio quitado, agrietado o roto.
  • Page 6: Fireplace Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualifi...
  • Page 7 Innovative Hearth Products General Information DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 APPLIANCE OPERATION NOTICES These fi replaces are vented gas appliances. Do not burn wood or other material in these appliances. These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
  • Page 8: Packaging List

    Innovative Hearth Products General Information DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 INSTALLATION PACKAGING All models include The assembled vented gas fi replace heater is packaged with: • Literature Kit (envelope in bottom compartment containing Installation and Operation Instructions (this manual), Hot Glass Safety Flyer, and Safety-In-Operation Warning Labels) •...
  • Page 9: Gas Pressure

    Innovative Hearth Products General Information DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 BTU Input Table 1 - Input Rate, Gas Valves Input Rate (BTU/HR) Models Natural Gas Propane Gas 33” Models 12,000 10,000 35” Models 14,000 12,000 40” Models 16,000 15,000 45”...
  • Page 10: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products General Information DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Orifi ce Sizes—Sea Level to High Altitude These fi replaces are tested and approved for installation at elevations of 0–4500 ft (0–1372 m) above sea level using the standard burner orifi ce sizes (Table 5). For elevations above 4500 ft, contact your gas supplier or qualifi ed service technician.
  • Page 11: Manufactured Home Requirements

    Innovative Hearth Products General Information DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 12: Vent Termination Clearances

    Innovative Hearth Products General Information DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 VENT TERMINATION CLEARANCES These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 13 Innovative Hearth Products General Information DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Table 7 - Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall Openable Fixed Closed...
  • Page 14: Minimum Clearances To Combustibles

    Innovative Hearth Products General Information DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fi replace is approved with zero clearance to combustible materials on all sides (Table 8), with the following exception: The unit may not be recessed (allowance made for mantel legs / side trim in Figure 6). When the unit is installed with one side fl...
  • Page 15: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products General Information DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Table 10 - Combustible Shelf Height—Rear Vent Rear Vent with two 90° Elbows Model 3” clearance from shelf to Secure Vent ® Secure Flex ® (fl ex elbow) top of fi...
  • Page 16: Installation

    Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions. Framing 1.
  • Page 17 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Table 11 - Fireplace Framing Specifi cations Model Framing NOTE: Dimension “D” is the construction to be 10-1/2 required framing depth when 33-3/4” 34-1/4” 36-7/8” 14-1/2” 19-5/8” 2 x 4, or larger. 33”...
  • Page 18: Prepare The Fireplace Top Spacers

    Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Prepare the Fireplace Top Spacers 1. The two (2) 4” standoff spacers on top of the fi replace cabinet are shipped fl at. Remove the screw adjacent to the detached end (Figure 8). 2.
  • Page 19 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Rough in the Electrical Supply, if Needed 1. As necessary, rough in the fi replace electrical supply per NEC and local codes. Install the [Optional] Blower Kit before Installation in the Framing 1.
  • Page 20: Vent System Preparation

    Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 VENT SYSTEM PREPARATION Select a Horizontal or Vertical Vent System 1. With the fi replace secured in the framing, determine the vent route and identify the exterior termination location. The following sections describe vertical (roof) and horizontal (exterior wall) vent applications.
  • Page 21: Install The Vent Restrictor (If Necessary)

    Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Install the Vent Restrictor (if necessary) 1. Use the vent run descriptions in Figure 12 to determine if a vent restrictor is necessary. 2. If necessary, assemble the vent restrictor and wing as detailed in Figure 12 and 15. 3.
  • Page 22: Connecting The Vent Pipe

    Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Vent Restrictor with Horizontal Terminations When horizontally terminating a vent system with a vertical vent run up to 4 ft through an exterior wall, no vent restrictor is required. If installing more than 4 ft of vertical venting, install the restrictor (Figure 14), from inside or outside the unit, in the inner fi...
  • Page 23: Vent Section Length Table

    Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Vent section length table Table 15 will assist calculating how many vent sections are needed for the planned vent confi guration. When a vent section is engaged with another section, its effective length will be 1-1/2” shorter. Table 15 - Vent Section Length Nominal Section Nominal Section Length...
  • Page 24: Install The Vent System

    Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Clearance to combustibles Maintain the minimum clearance to combustibles (e.g., framing, attic, ceiling insulation, etc.). For all vertical runs: • 1” (26 mm) from all sides NOTE: Attic insulation shield (H3907) must be installed when blown or loose-fi ll insulation is used, and is recommended for all attic installations.
  • Page 25 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Vertical (Offset) Installation 1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent Length on Pages 22 and 23 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists.
  • Page 26 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 8. Change vent direction of horizontal/inclined run—Install the SV4.5E45 and SV4.5E90 elbows in the same manner as the straight vent sections. See Vent elbows on Page 22 for more information. 9.
  • Page 27 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Vertical Vent Figures/Tables NOTE: Secure Vent ® rigid vent pipe is shown in the fi gures; Secure Flex ® fl exible vent pipe may also be used. NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane of approximately 1/4”...
  • Page 28 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Table 18 - Top Vent—Two 90° Elbows Table 19 - Rear Vent—Three Elbows Table 20 - Top Vent—Three Elbows When using ® Secure Flex , use Ceiling fi restop/ ceiling fi...
  • Page 29 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 30 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 9. Change vent direction—At transition from or to a horizontal/inclined run, install SV4.5E45 or SV4.5E90 elbows in the same manner as the straight vent sections. The elbows feature a twist section to allow them to be routed about the center axis of their initial collar section to align with the required direction of the next vent run element.
  • Page 31 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Figure 27 - Installing the Horizontal Termination To help minimize water infiltration it is recommended that the Firestop/Spacer (SV4.5HF) be installed on the exterior Termination side of the wall. 7”...
  • Page 32 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Table 21 - Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6 to 9 1/4” (152 to 235 mm) Termination Kit and 6”...
  • Page 33 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Table 24 - Top Vent—One 90° Elbow, Elbow Connection NOT at Fireplace H Maximum V Minimum feet meters feet meters 1.524 0.305 3.048 0.610 4.572 0.914 7.62 1.524 Ceiling fi...
  • Page 34 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Table 27 - Rear Vent—Three 90° Elbows H + H Maximum H Maximum V Minimum feet meters feet meters feet meters Wall fi restop/spacer 1.524 0.610 0.305 SV4.5HF ** 3.048 1.219 0.610...
  • Page 35 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Vertical or Horizontal Venting Using Secure Flex Kits and Components ® When Secure Flex kits are used in a rear fl ue, horizontal termination installation, at least 1 ft of vertical rise is required. ®...
  • Page 36: Complete The Field Wiring

    Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 d. 1-3/4” from the end, and that it is free from damage or tears. e. Slide the gear clamp down and tighten it fully to secure the fl exible vent to the adaptor outer collar approximately 3/4”...
  • Page 37 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Figure 31 - Wiring Diagrams - Electronic Gas Valve JUNCTION BOX AC/DC 120V AC POWER ELECTRONIC PILOT ASSEMBLY ADAPTOR IGNITER ROD HOOD NEUTRAL FLAME SENSOR GROUND PILOT PROFLAME VALVE PILOT TUBE SENSOR CABLE...
  • Page 38 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Figure 32 - Wiring Diagram - Millivolt Gas Valve Figure 33 - Junction Box Wiring, 120 V, 60 hz, 1 phase THERMOPILE Wall-mounted ON/ APPLIANCE- MOUNTED ON/OFF SWITCH OFF blower switch (OPTIONAL) or variable speed TP-TH...
  • Page 39: Install The [Optional] Blower Kit After Installation In The Framing

    Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 WARNING Electronic models of these appliances are equipped with a three-prong (grounding) plug utilized in connecting the electronic components to the junction box in the lower compartment. This grounding plug provides protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
  • Page 40: Verify Proper Fireplace Operation

    Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Figure 34 - Control Compartment Figure 35 - Gas Line Connection 3/8 NPT x 3/8” 1/2 x 3/8” Flare Flare fi tting shutoff valve valve 3/8” Flex tubing (Optional) fl exible gas line connector stub 1/2 x 3/8”...
  • Page 41: Optional: Install The Firebox Liners

    Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Electronic Fireplace Inspection To light the burner, turn ON the wall or remote control switch. Ensure the igniter lights the pilot. The pilot fl ame should engulf the fl ame rod (Figure 37). Figure 36 - Millivolt Pilot Figure 37 - Electronic Pilot Hood...
  • Page 42 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Air Shutter Adjustment Guidelines • If smoke or soot is present, fi rst check the log set positioning to ensure that the fl ames are not impinging on any of the logs.
  • Page 43: Install The Hood

    Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Install the Hood NOTE: All models must have a hood installed prior to operation. 1. Install the hood by sliding it into the slots on the lower edge of the cabinet top. NOTE: To install the non-combustible fi...
  • Page 44 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 INSTALLER - ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affi xed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD...
  • Page 45: Installation Accessories

    Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 INSTALLATION ACCESSORIES Table 31 - Listed Secure Vent ® Components Catalog Catalog Model Description Model Description Number Number Rigid, Horizontal, Compact The following fl ashing comes packaged with a storm collar Termination with Firestop/Spacer F1797 SV4.5HTKCT...
  • Page 46 Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 ® Table 32 - Listed Secure Vent Components Catalog Catalog Model Description Model Description Number Number 96K93 SV4.5SU Support Strap 77L76 SV4.5E45 45° Elbow Horizontal Riser Kit, 14”(see 99L02 SV4.5HRK14 750146M) 77L77...
  • Page 47: Gas Conversion Kits

    Innovative Hearth Products Installation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fi...
  • Page 48: Operation

    Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 49 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD À LA SÉCURITÉ D’UTILISATION EN OPERACIÓN Your fi...
  • Page 50 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Burn-in Period The fi rst few times this fi replace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 51 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 NOTE: Do NOT wire more than one valve to the burner control switch. This will help prevent excessive resistance in the burner circuit, that can cause burner operation problems. Electronic Fireplaces Detailed lighting instructions are found on Pages 66 and 67.
  • Page 52 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Installing the logs, volcanic stone, and glowing embers WARNING • Turn OFF all gas and electricity to the appliance before installing the volcanic stone, embers, and logs. • Do NOT install the logs until the appliance has been completely installed, the gas line connected and tested for leaks, and the initial burner operation has been confi...
  • Page 53 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Installing the logs - 33” and 35” Traditional Models The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between fl ame peaks, so they do not impinge the fl...
  • Page 54 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Installing the logs - 40” and 45” Traditional Models The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between fl ame peaks, so they do not impinge the fl...
  • Page 55 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Installing and removing the glass door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage—Do not scratch or handle roughly while reinstalling the glass door frame.
  • Page 56 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated fi rmly. Ensure it is properly located. Make sure the bead is not rolled into the channel at the top of the door, but remains fl...
  • Page 57: Maintenance

    Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 MAINTENANCE Refer to the Maintenance Schedule on Page 60 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fi replace operation after servicing. WARNING Turn OFF gas and electrical power to the fi...
  • Page 58 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Inspecting the glass gasket Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities, and seated fi rmly. Cleaning the control compartment Keep the control compartment clean by vacuuming or brushing it out at least twice a year.
  • Page 59 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Glass Media Removing and cleaning the glass media CAUTION Risk of personal injury. Allow the media to completely cool before handling. Use a clean, dry, empty shop vac to remove glass media. Wash the media in warm, soapy water. Rinse and dry before reinstalling.
  • Page 60 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Table 40 - Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By Performed By Inspecting/Cleaning Burner, Logs Qualifi...
  • Page 61: Accessory Components

    Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 ACCESSORY COMPONENTS Touch-Up Paint Kits Repair minor scratches and discoloration of the fi replace black painted surfaces with the touch-up paint kits. Table 42 - Touch-Up Paint Kit Catalog No. Description F1881 Black touch-up paint, fi...
  • Page 62 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 ACCESSORY COMPONENTS (continued) Thermostatic Control Kits Feature a thermostatic ON/OFF mode as well as manual ON/OFF operation. Table 47 - Thermostatic Control Kits RC-S-STAT, Thermostatic or manual operation Catalog Number •...
  • Page 63 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 ACCESSORY COMPONENTS (continued) Unit-Mountable Rocker Switch Kit This rocker switch kit can be installed directly in the control compartment to provide ON/OFF operation in lieu of a wall switch. Table 49 - Unit-Mountable Rocker Switch Catalog Model...
  • Page 64: Lighting Instructions

    Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 LIGHTING LABEL, MILLIVOLT GAS VALVE - ENGLISH FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 65 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 LIGHTING LABEL, MILLIVOLT GAS VALVE - FRENCH POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 66 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 LIGHTING INSTRUCTIONS, ELECTRONIC - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 67 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 LIGHTING INSTRUCTIONS, ELECTRONIC - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 68: Troubleshooting

    Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 TROUBLESHOOTING Before troubleshooting, ensure that the fi replace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fi replace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 69 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Table 54 - Troubleshooting Electronic Systems SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Nothing happens a. Remote is not functioning properly. Check that the wall switch plate is set to REMOTE. when the fi...
  • Page 70: Replacement Parts

    H1264 Assembly Harness, Control H8601 H8601 H8601 H8601 Glass Media, 5 lb bag—Refl ective Black H8412 H8412 H8412 H8412 (Contemporary) Log Set F1885 H7666 H7667 H7480 Log Grate H7719 H7719 H7720 H7720 Superior ® Badge (logo) J8150 J8150 J8150 J8150...
  • Page 71 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 REPLACEMENT PARTS (continued) BURNER ORIFICES 33” Models 35” Models 40” Models 45” Models Catalog Catalog Catalog Catalog Number Number Number Number Brass Orifi ce, Female—Natural Gas H8303 21L82 J7910 60J80 (#51) (#49)
  • Page 72 Innovative Hearth Products Operation DRT2000 and DRC2000 Direct-Vent Fireplaces 900004-00, 03/2017 Figure 56 - Replacement Parts Back view not representative of all fi replace models...
  • Page 73 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...
  • Page 74 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...
  • Page 75: Warranty

    Brand Gas Fireplaces, Stoves and Inserts 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior ® Brand gas fi replace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The product body, fi rebox and barrier carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 76 Installation and Operation Instructions Innovative Hearth Products 900004-00, 03/2017 DRT2000 and DRC2000 Direct-Vent Gas Fireplaces SuperiorFireplaces.us.com Record the following important information about your fi replace: Fireplace model number Fireplace serial number Date fi replace was Installed Type of gas fi replace uses Dealer name Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifi...

Table of Contents