Installing the Connection Housing
9 mm
3.
4.
Centering groove
Note:
See page 37 for numbered parts
description.
5.
90º
Installation on a Wall
Turn T-slot bolt 90° for all installation
steps.
1. Position the connection housing
onto the mounting rails
into the retaining plates
2. Align the connection housing.
IMPORTANT
The tube holders on the installation rails
must be in alignment with those in the
connection housing; align with string if
necessary.
3. Mark the fixing points at the back of
the connection housing. Use the
centering groove as a template.
3
4. Drill holes, Ø
/
" / 9mm
8
5. Secure the connection housing with
T-slot bolt 5 ,washer 6 and nut 7.
6. Where several collectors are installed
one above the other, continue with
"Joining the Connection Housings"
on the following page, otherwise
continue with "Installing the Vacuum
Tubes and the Collector Temperature
Sensor" on page 43.
and click
.
41