Installing the Connection Housing
2.
Note:
Please see page 17 for numbered parts
description.
1.
Installation on Sloped Roofs
(
Vertical Tube Orientation)
3.
Turn T-slot bolt 90° for all installation
steps.
1. Position the connection housing
onto the mounting rails
into the retaining plates
2. Align the connection housing.
IMPORTANT
The tube holders on the installation rails
must be in alignment with those in the
connection housing; align with string if
necessary.
3. Tighten the mounting rails with the
clamping brackets
4. If several collectors are to be
mounted adjacently, go to subsection
entitled "Joining the Connection
Housings"on page 42, otherwise go
to subsection "Installing the General
Connection Kit and Collector
Temperature Sensor" on page 43.
and click
.
.
23