Installation on Flat Roofs

Mounting Collectors to Ballast Weights

Ballast weights required to secure against slipping
Installation height above
ground level
Model SD2A
Ballast A
Ballast B
*1
Securing against slipping requires no additional attachment to roof.
Ballast weights required to secure against lifting
Installation height above
ground level
Model SD2A
Ballast A
Ballast B
*2
Securing against lifting requires additional attachment to roof or structure
with wires or cables.
26
This installation method allows for collectors to be mounted on a flat roof with
tubes parallel to the roof. Ballast weights are typically used to hold collectors in
place, but collectors can also be mounted to substructure frames.
Flat roofs with gravel filling:
Clear gravel from position of concrete slabs.
With plastic roofing:
Place concrete slabs only on protective interlayers, e.g. protective mats.
*1
m
<8
ft
<26
2
2m
3m
lb/piece
48.4
72.6
kg/piece
22
lb/piece
57.2
85.8
kg/piece
26
*2
m
<8
ft
<26
2
2m
3m
lb/piece
33.0
48.4
kg/piece
15
lb/piece
39.6
59.4
kg/piece
18
8-20
26-66
2
2
2
2m
3m
2m
96.8
143.0
145.2
33
44
65
66
101.2
151.8
147.4
39
46
69
67
8-20
26-66
2
2
2
2m
3m
2m
68.2
101.2
105.6
22
31
46
48
70.4
107.8
105.6
27
32
49
48
20-100
66-328
2
2
3m
215.6
98
222.2
101
20-100
66-328
2
2
3m
158.4
72
160.6
73