Installing The Connection Housing - Viessmann VITOSOL 200-T SD2A 2m2 Series Installation Instructions Manual

Table of Contents

Advertisement

Installing the Connection Housing

Note:
See page 9 for numbered parts
description.
Installation on Sloped Roofs
(Horizontal Tube Orientation)
Turn T-slot bolt 90° for all installation
steps.
1. Position the connection housing
onto the mounting rails and click into
the retaining plates
.
2. Align the connection housing.
IMPORTANT
The tube holders on the installation rails
must be in alignment with those in the
connection housing; align with string if
necessary.
3. Mark the fixing points at the back of
the connection housing.
Use the centering groove
template.
3
4. Drill holes, Ø
/
" / 9mm.
8
5. Secure the connection housing
the mounting rail
.
6. If several collectors are to be
mounted one above the another, go
to subsection entitled "Joining the
Connection Housings" on page 42,
otherwise go to subsection "Installing
the General Connection Kit and
Collector Temperature Sensor" on
page 43.
as a
to
15