TECHNICAL DATA

Mains voltage
Mains supply
Primary current
I
TIG
max
I
MMA
max
No- -load power demand when in the
energy--saving mode, 6.5 min. after welding
Setting range
TIG
MMA
Permissible load at TIG
35 % duty cycle
60% duty cycle
100% duty cycle
Permissible load at MMA
30 % duty cycle
60% duty cycle
100% duty cycle
Power factor at maximum current
TIG
MMA
Efficiency at maximum current
TIG
MMA
Open- -circuit voltage
MMA
Operating temperature
Transportation temperature
Constant sound pressure at no- -load
Dimensions lxwxh
with cooling unit
Weight
with cooling unit
Insulation class transformer
Enclosure class
Application class
Mains supply, S
sc min
Minimum short circuit power on the network in accordance with IEC 61000--3--12
Duty cycle
The duty cycle refers to the time as a percentage of a ten--minute period that you can weld at a cer-
tain load without overloading. The duty cycle is valid for 40˚C.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP23 is designed for indoor and outdoor use.
bt37e
Tig 3001i
400 V ±10%, 3∼ 50/60 Hz
S
1.4 MVA
sc min
13 A
19 A
30 W
4 -- 300 A
16 -- 300 A
300 A / 22 V
240 A / 19.6 V
200 A / 18 V
300A / 32 V
230 A / 29.2 V
190 A / 27.6 V
0.9
0.89
81 %
84 %
67 V
--10 to +40˚C
-- 20 to +55˚C
< 70 dB (A)
652 X 249 X 423 mm
714 X 249 X 693 mm
33.5 kg
54 kg
H
IP 23
- - 17 - -