DIRECTIVE DECLARATION OF CONFORMITY ESAB AB, Welding Equipment, SE--695 81 Laxå, Sweden, gives its unreserved guarantee that weld- ing power source Tig 3000i from serial number 802 are constructed and tested in compliance with the standard EN 60974--1 /--3 and EN 60974--10 (Class A) in accordance with the requirements of direc- tive (2006/95/EC) and (2004/108/EEC).
Page 14
MALFUNCTION - Call for expert assistance in the event of malfunction. Read and understand the instruction manual before installing or operating. PROTECT YOURSELF AND OTHERS! ESAB can provide you with all necessary welding protection and accessories. WARNING! Do not use the power source for thawing frozen pipes.
INTRODUCTION The Tig 3000i is a TIG welding power source, which can also be used for MMA welding. ESAB’s accessories for the product can be found on page 25. Equipment The power sources is supplied with: Instruction manual for the welding power source, instruction manual for the control panel and 5 m return cable.
TECHNICAL DATA Tig 3000i Mains voltage 400 V, ±10%, 3∼ 50/60 Hz Mains supply 1,4 MVA sc min Primary current 14.1 A 19 A No- -load power demand when in the 30 W energy--saving mode, 6.5 min. after welding Setting range 16--300 A 4--300 A Permissible load at TIG...
INSTALLATION The installation must be executed by a professional. Note! Mains supply requirements High power equipment may, due to the primary current drawn from the mains supply, influence the power quality of the grid. Therefore connection restrictions or requirements regarding the maximum permissible mains impedance or the required minimum supply capacity at the interface point to the public grid may apply for some types of equipment (see technical data).
Note! The mains cable areas and fuse sizes as shown above are in accordance with Swedish regulations. Use the welding power source in accordance with the relevant national regulations. Note! The welding power source is designed for connection to a 230 / 400 volt system with four conductors.
MAINTENANCE Regular maintenance is important for safe, reliable operation. CAUTION! All guarantee undertakings from the supplier cease to apply if the customer himself attempts any work in the product during the guarantee period in order to rectify any faults. Only those persons who have appropriate electrical knowledge (authorized personnel) may remove the safety plates.
Control panel Origot TA23, Origot TA24 0460 032 Instruction manual Control panel TA23 0459 945 Instruction manual Control panel TA24 Instruction manuals and the spare parts list are available on the Internet at www.esab.com - - 24 - - Edition 100114 bt30o...
Need help?
Do you have a question about the Origo Tig 3000i and is the answer not in the manual?
Questions and answers