4.5.3.
Document Jam (030) or Skewing
START
Is the ADF Door closed?
Yes
Do all sensors on the SNS PCB
operate normally?
Yes
Does the Feed Roller have drive
and sufficient friction?
Yes
Is the document path clear of
foreign particles or paper?
Yes
Is the Transmitting mechanism
operating properly?
Yes
END
No
Close the ADF Door firmly.
No
Clean or replace the SNS PCB.
No
Clean the surface of the roller
with isopropyl alcohol (Sect. 2.7).
No
Remove the foreign particles or
paper from the document path.
No
Adjust or replace any defective
parts.
165