Pop-Up Fault Status Screens - Time And Energy Modes - Dukane iQ Series User Manual

Dukane iq series ultrasonic hand held systems
Hide thumbs Also See for iQ Series:
Table of Contents

Advertisement

User's Manual
Status Text Displayed
Latch On Fault ENABLED
Process Fault
Set Weld
Time Not Reached
Enter Clears Fault
Process Fault
Set Weld
Energy Not Reached
Enter Clears Fault
Process Fault
Peak Overload
Time Not Reached
Enter Clears Fault
Process Fault
Frequency Lock Lost
Energy Not Reached
Enter Clears Fault
Process Fault
Input Undervoltage
Energy Not Reached
Enter Clears Fault
Table 7-2 Pop-Up Fault Status Screens - Time and Energy Modes
Page 4
Process Fault Satus Screens - Time and Energy Modes
Latch On Fault DISABLED
Process Fault
Set Weld
Time Not Reached
Process Fault
Set Weld
Energy Not Reached
Process Fault
Average Overload
Time Not Reached
Process Fault
Over Temperature
Energy Not Reached
System Status or Fault Explanation
Set Weld Time Not Reached, or
Set Weld Energy Not Reached - appears if the
weld ends before the set time or energy is reached
(respectively) due to operator error, or
because the weld was intentionally aborted.
Peak Overload, Average Overload, Frequency Lock
Lost, Input Undervoltage, or Over Temperature is
displayed in place of Set Weld Time not Reached,
or Set Weld Energy not Reached, if the weld ends
before the set time or energy is reached due to a
process or generator fault.
Dukane Manual Part No. 403-577-00