User's Manual
Control Keys, continued
AMP
Set the ultrasound amplitude output level in a range from
20 - 100%.
Typically amplitude is set to 100%.
TIME
Use this key to select time as the primary method of
welding. Set the weld time (seconds).
ENERGY
Use this key to select energy as the primary method of
welding. Set the weld energy (joules).
HOLD
Hold is a time period beginning after the weld portion
of the cycle is complete. The operator holds the probe in
place until an audible alarm indicates that the Hold time is
finished. Hold can be set to a maximum of 5.0 seconds.
ENTER
Press the ENTER key to select a menu item, and move to
the next level of the menu. Think of it as a "forward" key.
When pressed it also confirms and stores a selection in
memory. It is also used to reset a latched condition.
Arrow Keys
Press the right and left arrow keys to move the cursor to
the right or left.
+
-
and
Keys
Press these keys to increase or decrease the value of a
selected digit.
CANCEL
Press CANCEL to return to the previous screen or cursor
position. Think of it as a "back" key. Press this key when
you do not want to store the selection in memory.
Page 
System LCD Display
This high resolution, multi-line display provides a clear
graphic interface to the operate and in-cycle screens
needed to monitor and program the system.
Power Bar Graph
The Power Bar Graph appears at the bottom of the
LCD display. It contains 20 segments that represent the
generator's range of power from 0% at the far left of
the bar graph to 100% of power at the far right. Each
segment, then equals 5% of the total.
In the example below, 40% of the available power is used
during the weld cycle. The display shows an In Cycle
screen (while U/S is active).
IN CYCLE
Frequency: 40087 Hz
Power:
# 2
In the example below, 10% of the available power was
used in the last weld. The display shows an Operate
screen (while U/S is inactive).
Weld by Time
Weld Time 1.500 S
Weld Energy 24 J
# 1
Make sure the stack is prop-
erly assembled before it is
connected to the system. The
horn should never come in
direct contact with a metal fix-
ture or anvil when ultrasound
is activated.
Dukane Manual Part No. 403-577-00
In Cycle
screen
225 W
40% of power used
Operate
screen
10% of power used
CAUTION