SETUP
continued
Saving the Current Setup
Try using your navigation skills on this practical
example:
1.
Follow instructions on Page 24 to set the mode to
Weld by Time. Set the time to 1.520 seconds.
See Figure 5-18.
2.
Press SETUP and then press the
get an EMPTY Setup Maintenance screen.
See Figure 5-19.
3.
Use the right arrow key to select Store, and then press
ENTER. You will be returned to the Operate screen.
4.
Confirm that your setup has been stored in memory
by going back to SETUP. Your new setup should
appear, just as it does in Figure 5-20.
Selecting a Setup
To select a setup previously stored:
1.
Press SETUP.
2.
With Load highlighted, use the
the number of the setup you want.
3.
Press ENTER.
4.
The Operate screen will display this selection as a
number in the lower left hand corner.
Deleting a Setup
To delete a setup previously stored:
1.
Press SETUP.
2.
With Delete highlighted, use the
the number of the setup you want.
3.
Press ENTER, and a pop-up screen will ask you to
confirm your selection. Make your choice, and press
ENTER.
4.
Check that the setup is deleted. Press SETUP, and the
Setup Maintenance screen will show EMPTY for the
setup you just deleted.
Dukane Manual Part No. 403-577-00
+
key until you
+ -
keys to select
+ -
keys to select
Weld by Time
Weld Time
1.520 S
Hit Enter To Accept
Hit Cancel To Abort
Figure 5-18 Save Current Setup
Setup Maintenance
Delete
Store
Load
Setup #
1
EMPTY
Figure 5-19 Store in Setup Maintenance
Setup Maintenance
Store
Delete
Load
Mode: Manual
Setup #
6
T: 1.520 S
A: 100%
E: 0 J
H: 0.0 S
Figure 5-20 New Setup 3