REMOTELY MANAGING YOUR INTERACTIVE FLAT PANEL

Power modes

An interactive flat panel has three distinct power modes:
On
l
Power Save
l
Standby
l
All commands are available when the interactive flat panel is on. Some commands are available
when the interactive flat panel is in Standby mode.
Room control system programming commands
and responses
To access interactive flat panel information or to adjust interactive flat panel settings using the
room control system, type commands after the command prompt (>), and then wait for the
response from the interactive flat panel.
CORRECT
>get contrast
contrast=55
If you type a command that the room control system doesn't recognize, you receive an invalid
command response.
In the example below the user included a space in the contrast command.
INCORRECT
>set con trast=65
invalid cmd=set con trast=65
NOTES
Use ASCII formatted commands.
l
Commands aren't case-sensitive.
l
Review each entry carefully before you press ENTER.
l
Don't send another command until you receive the response and the next command
l
prompt.
41