Symphony (AUI) Enable

FIELD
TITLE and DATA ENTRIES
Symphony (AUI) Enable
*189
0 = disabled
1 = partition 1
2 = partition 2
3 = common lobby

Keypad Programming Fields

NOTE: Each keypad must be assigned a unique address. Keypads programmed with the same address will give
unpredictable results.
FIELD
TITLE and DATA ENTRIES
Keypad 2 Device Address 17
*190
Entry 1 – Partition Assignment:
0 = keypad disabled
1 = partition 1
(VISTA-20P)
2 = partition 2
3 = common
Entry 2 – Sound Option:
0 = no suppression
1 = suppress arm/disarm and E/E/ beeps
2 = suppress chime beeps only
3 = suppress arm/disarm, E/E/ beeps and
chime beeps
Keypad 3 Device Address 18
*191
See field *190 for entries.
Keypad 4 Device Address 19
*192
See field *190 for entries.
Keypad 5 Device Address 20
*193
See field *190 for entries.
Keypad 6 Device Address 21
*194
See field *190 for entries.
Keypad 7 Device Address 22
*195
See field *190 for entries.
Keypad 8 Device Address 23
*196
See field *190 for entries.
Exit Time Display Interval
*197
0 = no display
1-5 = seconds between display updates
Display Partition Number
*198
0 = no
1 = yes
ECP Fail Display
*199
0 = 3-digit display ("1" + device address)
1 = 2-digit fixed-display as "91"
EXPLANATION
APPLIES TO VISTA-20PS ONLY.
Enter each AUI's home partition.
AUI 1 address must be set to 1.
AUI 2 address must be set to 2.
NOTE: A minimum of one standard keypad must also be installed
when AUI is used. Use of AUI does not affect the number of standard
keypads supported.
EXPLANATION
Keypad 2
Entry 1: For VISTA-20P, enter the partition in which the keypad is
located; for VISTA-15P, enter 1 to enable, or 0 to disable.
/enabled
(VISTA-15P)
Entry 2: Enter the desired sound option for this keypad.
NOTE: Address 16 is reserved for keypad 1, which is automatically
set to partition 1 with all sounds enabled.
Keypad 3
See field *190 for explanation.
Keypad 4
See field *190 for explanation..
Keypad 5
See field *190 for explanation.
Keypad 6
See field *190 for explanation.
Keypad 7
See field *190 for explanation.
Keypad 8
See field *190 for explanation.
If enabled, keypads display the exit time remaining after arming the
system, with display updates at the interval selected (i.e. if the exit
delay is 30 seconds and "2" is selected in this field, the keypad display
refreshes every 2 seconds, displaying 30, 28, 26, 24, etc.).
An interval greater than "1" may be necessary for some older keypads
to allow users time to enter key presses between display updates.
If selected, the partition number is displayed in the upper-left corner
of the display. This is useful when using the GOTO partition function.
Select "0" if using Alpha keypads and/or 3-digit Fixed-Word Display
keypads. ECP faults will display "1" plus the device address (00-30) of
device causing the fault (e.g., faults on device 07 display as "107").
Select "1" if using 2-digit Fixed-Word Display keypads (e.g., certain
6128 series keypads). If selected, ECP faults for all devices will display
as "91" on 2-digit displays, and "191" on 3-digit or Alpha keypads.
Data Field Programming
4-13