5.2.7. Install Settings
The settings in Install Settings page can only be adjusted by qualified
installers or engineers. Changing these settings may result in damage
to the inverter and other equipment.
To enter Install Settings page, users have to enter correct password.
There are 3 sets of password with different permissions: user level, installer
level, and manufacturer level. The following sub-sections will introduce
the setting items in Install Settings page of user level and installer level.
5.2.7.1. Inverter ID
Inverter ID is used in RS-485 communication, for PC recognizing the
inverter. If users connect several inverters together via RS-485, each
inverter must have different ID.
►
Inverter ID: 002
Insulation
Country
Grid Settings
►
Inverter ID: 002
Insulation
Country
Grid Settings
►
DC Injection
Dry Contact
RCMU
EPO
Normal Close
AC Connection
►
Anti-islanding
Max Power
Return to Factory
Figure 5-9 Install settings page
Figure 5-10 Inverter ID page
CAUTION
User Level:
-
Inverter ID
-
Insulation
-
Country
-
Dry Contact
-
EPO
-
AC Connection
-
Max. Power
Installer Level:
-
Inverter ID
ON
-
Insulation
-
Country
-
Grid Settings
-
Dry Contact
-
EPO
3P4W
-
AC Connection
ON
-
Max. Power
52500W
Manufacturer Level:
-
All Settings
ENT
EXIT
45
Turn on PV inverter
Setting ID:
ID = 002