Download Print this page

Grid Settings - Delta RPI M30A Operation And Installation Manual

Grid-tie transfomerless solar inverter

Advertisement

逆变器开机

5.2.7.4. Grid Settings

Grid Settings页面包含各种电压与频率保护值,这些保护值乃依据各电力
法规所建立,若无特殊需求请勿修改任何保护值。
Inverter ID: 002
Insulation
Country
Grid Settings
Voltage Protection
ENT
Freq. Protection
Reconnect T
P Ramp Up
6000%/m
EXIT
Voltage Protection
EXIT
Freq. Protection
Reconnect T
P Ramp Up
6000%/m
图5-13 Grid Settings 页面
High Off
ENT
High On
600s
High Off T
EXIT
Low Off
Low On
EXIT
Low Off T
Hi Off Slow
Hi On Slow
Hi Off Sl T
EXIT
Lo Off Slow
Lo On Slow
Lo Off Sl T
High Off
ENT
High On
600s
High Off T
Low Off
EXIT
Low On
EXIT
Low Off T
Hi Off Slow
Hi On Slow
Hi Off Slow T
EXIT
Lo Off Slow
Lo On Slow
Lo Off Slow T
122
276.0V
259.0V
0.3s
If user enters wrong settings
184.0V
Wrong Settings
219.0V
0.3s
Press ▲&▼ 5s
276.0V
259.0V
Do you want to set
U to the max range?
600.0s
184.0V
219.0V
1.0s
51.50Hz
50.05Hz
0.1s
If user enters wrong settings
47.50Hz
Wrong Settings
47.55Hz
0.1s
65.00Hz
Press ▲&▼ 5s
64.95Hz
Do you want to set
F to the max range?
5.0s
45.00Hz
45.55Hz
5.0s
Yes / ►No
Yes / ►No

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Rpi m50a