6.1 Replace Surge Protection Device (SPD)

RPI M50A_120 model have surge protection device (SPD) at both DC and
AC side. Table 6-1 reveals the specifications of SPD.
SPD(DC)
Part number: GPU1-ZS1000 Y
Work voltage:1000 Vdc
Work Amp In (8/20): 20kA
Rate Amp I max(8/20): 40kA
Temperature: -40 C~85 C
Item fail: Green light will turn off
Manufacturers: ShangHai GEHE Lighti

6.Maintenance

WARNING
Part number: GPU1-C4/690/1P Y
Work voltage: 690 Vac
Work Amp In (8/20): 15kA
Rate Amp Imax (8/20): 30kA
Temperature: -40 C~85 C
Item fail: Red upright bulb
Manufacturers: ShangHai GEHE Lighti
Table 6-1 SPD Specifications