Sony DNW-A100 Operation Manual page 103

Digital video hybrid recorder
Hide thumbs Also See for DNW-A100:
Table of Contents

Advertisement

Item number Item name
310
REC INHIBIT
316
CONFIDENCE PB MODE
318
EDIT RETRY
320
DIGITAL AUDIO
PROCESS ON EDIT
POINT
321
V FLOW D-D
(Version 2.00
or later)
322
A FLOW D-D
(Version 2.00
or later)
323
EXT FLOW DL
(Version 2.00
or later)
Menu items in the 300s, relating to editing operations (Continued)
Settings
Select the conditions under which recording is inhibited when the REC INHIBIT
switch on the subsidiary control panel is set to ON.
ALL : All tape recording is inhibited.
CRASH: Normal tape recording is inhibited. Select this setting when you wish to
carry out assemble editing.
Note
When the REC INHIBIT switch is set to ON, the REC INHIBIT indicator on the
lower control panel lights. If an operation inhibited by this item is attempted, the
REC INHIBIT indicator flashes.
Select whether or not to carry out CONFI playback while recording on the tape.
OFF : No CONFI playback.
ON: CONFI playback.
For two-VTR editing, set when this unit is used as the recorder. Selects the
operation if the recorder was not synchronized in time.
OFF: Editing is not carried out, and the unit stops.
ON : The editing is automatically retried (up to twice).
Select the treatment of audio at tape or disk edit points.
CUT: Carry out a cut (possibly resulting in audio discontinuities at the edit point).
FADE : Fade out and fade in.
Set the video signal flow for real-time editing (video and audio levels can be
adjusted) when MASTER or PROGRAM has been selected as the player and
PROGRAM has been selected as the recorder.
INT : Record signals from the player to the recorder internally in this unit.
EXT: Output signals from the internal player of this unit to an external device, and
input signals from the external device to the recorder.
Selecting EXT makes it possible to re-input signals to this unit after processing by
a video effector or other external device. In this case, select the input signals with
the VIDEO INPUT SELECT switch on the upper control panel.
Set the audio signal flow for real-time editing (video and audio levels can be
adjusted) when MASTER or PROGRAM has been selected as the player and
PROGRAM has been selected as the recorder.
INT : Record signals from the player to the recorder internally in this unit.
EXT: Output signals from the internal player of this unit to an external device, and
input signals from the external device to the recorder.
Selecting EXT makes it possible to re-input signals to this unit after processing by
an external device. In this case, select the input signals with the AUDIO INPUT/
MIXING/MONITOR SELECT switch on the upper control panel.
Set the processing delay of this unit according to the processing delay of an
external device. This setting is required when item 321 (V FLOW D-D) is set to
EXT to carry out real-time editing by re-inputting video signals via a video effector
or other external device.
0 FR : 0 frame
1 FR: 1 frame
2 FR: 2 frames
Note
Differences in the delay between this unit and an external device will cause edit
points to be displaced and prevent correct editing.
7-13
Chapter 7 Menu System

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dnw-a50pDnw-a45Dnw-a45pDnw-a100pDnw-a50

Table of Contents