Unpacking and installation

4.1

Assembling the stand (accessory)

D B
BB
NOTE! Only place the heat pump on its short
side as shown in the figure below, otherwise
there is a risk of damaging it.
D B
BB
NOTE! All panels (except the front cover) must
be installed on the heat pump.
Figure 4: The heat pump can be placed on its short side for short
periods of time.
1.
Place the heat pump on its short side as shown in
the figure above.
2.
Remove the adjustable feet (six) if the stand is to be
used.
3.
Screw the two horizontal struts (1) in the two ends
(2) with the grooves (4) turned as illustrated below.
Use 8 x M6x10 screws. The curved edges of the hori-
zontal struts must be facing inwards.
2
1
4
Figure 5: Assembling the stand.
4.
Screw the adjustable feet (3) into the holes under
the ends.
5.
Install the entire stand on the heat pump.
6.
Carefully stand the heat pump up so that it is on the
stand.
3
VMBMH302
4.2

Positioning the heat pump

When positioning the heat pump, note the following:
D B
BB
The heat pump must be positioned some dis-
tance away from the ground as the defrost
function can cause ice build-up. It must be posi-
tioned on a stand (accessory) or suspended from
wall brackets.
D B
BB
When the heat pump is defrosting, water will
drip straight down under the unit. The area
around the heat pump must therefore be
correctly drained in order to catch the water
(approximately 2 litres per defrost). A drip tray
(accessory) that collects and leads the melt
water away can be installed.
D B
BB
The heat pump's adjustable stand must be posi-
tioned on a secure base such as wooden sleep-
ers, paving slabs or cast footings.
D B
BB
The heat pump has six adjustable feet that must
be adjusted to compensate for irregularities in
the surface on which it is sitting. All feet must be
in contact with the underlying surface. If the sur-
face is so irregular that the feet cannot compen-
sate for it, the installation engineer must remedy
this.
D B
BB
The heat pump must be positioned horizontally,
which is checked with a spirit level.
BB E B
T he heat pump does not have to be positioned
in any specific direction.
4
BB E B
N oise is produced from the heat pump when the
fan and compressor are in operation, remember
this when positioning to reduce disturbance in
your own home as well as to any neighbours.
BB E B
Remember that the heat pump must have a cer-
tain amount of room in order to function and for
servicing, see section 3.5 Space requirement.
1.
Move the heat pump to the installation site.
2.
Position the heat pump where desired.
3.
Adjust all six feet so that they are in contact with
the underlying surface and so that the heat pump is
level.
4.
Attach the supplied decals with the correct language
over the existing decals.
Installation – 11