13.1.5
Sub menu INFORMATION -> OPERAT. TIME
Used to show the operating time for each component. Time given in hours.
Menu selection
HEAT PUMP
AUX. HEAT 1
HOT WATER
13.1.6
Sub menu INFORMATION -> DEFROST
This menu is used to obtain information about outdoor unit defrosting and to make certain settings.
Menu selection
DEFROSTS
BETW. 2 DEFR
TIME LAST DEFR
DEFROST CURVE
MANUAL DEFR
Meaning
Compressor operating time for both heating and hot water pro-
duction.
Operating time auxiliary heat step 1.
Operating time hot water with compressor.
Meaning
Total number of defrosts carried out.
The operating time of the compressor in minutes between the 2
last defrosts.
The operating time of the compressor in minutes since last
defrost.
Here, the angle of the defrost curve can be changed using +
or – (Change the start temperature for defrost).
Use + or - to start a manual defrost.
VMBMH302
Factory setting
-
-
-
Factory setting
-
-
-
-7°C
(interval: -10°C / -4°C)
0 (interval: 0 / 1)
Service – 35