Drilling Holes For Brine Pipes; Unpacking And Installation; Setting Up - Danfoss DHP-H Installation And Service Instructions Manual

Danfoss heat pumps installation and service instructions
Table of Contents

Advertisement

3
Drilling holes for brine pipes
NOTE! Ensure that the holes for the insert pipes are posi-
tioned so that there is room for the other installations.
NOTE! The brine pipes shall have separate lead-ins.
The brine pipes must be insulated from the heat pump, through
the walls and outside the house all the way to the collector so as to
avoid condensation and prevent heat loss.
If the brine pipes are to be routed above ground, drill holes in the
walls for them.
If the brine pipes are to be routed below ground see the instruc-
tions below.
Figure 15: Drilling holes for brine pipes .
Position Name
1
Insert pipe
2
Brine pipe
3
Mortar
4
Sealant
1. Drill holes in the wall for the insert pipes (1) for the brine pipes.
Follow the dimension and connection diagrams in Section 2
Technical Data. If there is any risk of groundwater infiltration at
brine pipe lead-ins, watertight grommets must be used.
2. Position the insert pipes (1) in the holes sloping downwards.
The inclination must be at least 1cm every 30cm. Cut them at
an angle (as illustrated) so that rain water cannot get into the
pipes.
3. Insert the brine pipes (2) into the insert pipes in the installation
room.
4. Fill in the holes in the wall with mortar (3).
5. Ensure that the brine pipes (2) are centred in the insert pipes (1)
so that the insulation is distributed equally on all sides.
6. Seal the insert pipes (1) with a suitable sealant (foam) (4).
1
4
Unpacking and installation
4 .1
Setting up
• The heat pump has feet that can be adjusted 20 mm to compen-
sate for irregularities in the surface on which it is sitting. If the
surface is so irregular that the feet cannot compensate for it, the
installation engineer must remedy this.
• It is recommended that a condensation drain be installed from
the drain pipe of the drip tray while the heat pump is on its side.
The drain pipe opens through a hole in the base plate and has a
Ø 10 mm hose connection.
1. Move the heat pump to the installation site.
2. Remove the packaging.
Figure 16: Condensation drain connection
3. Install a condensation drain if required.
Figure 17: Adjusting the heat pump .
4. Set up the heat pump in the installation site.
5. Adjust the feet (1) so that it is standing horizontal.
VMBMA102

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dhp-lDhp-aDhp-c

Table of Contents