Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
OVEN SHUTDOWN THERMAL FUSE
Refer to page 4-22 for the procedure for ser-
vicing the oven shutdown thermal fuse.
1.
Turn off gas supply and disconnect power
to the range.
2.
Disconnect the wires from the oven shut-
down thermal fuse terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
oven shutdown thermal fuse terminals.
The meter should indicate a closed circuit
(0 Ω).
WARNING
Electrical Shock Hazard
CONVECTION FAN MOTOR
Refer to page 4-18 for the procedure for ser-
vicing the convection fan motor.
1.
Turn off gas supply and disconnect power
to the range.
2.
Disconnect the wires from the convection
fan motor terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
convection fan motor terminals. The meter
should indicate 8 to 12 Ω.
5-5