Installation Information; L.p. Gas Conversion - KitchenAid KDRP487MSS Technical Education

48?? dual fuel slide-in range
Hide thumbs Also See for KDRP487MSS:
Table of Contents

Advertisement

INSTALLATION INFORMATION

WARNING
Electrical Shock Hazard
Disconnect power before
servicing.
Replace all parts and panels
before operating.
Failure to do so can result in
death or electrical shock.
Shut off gas supply line valve.
Make all conversions before
turning gas supply valve back on.
Failure to follow these instructions
can result in explosion, fire, or
other injury.
NOTE: Gas conversion from natural to L.P.
gas must be done by a qualified installer.
1.
Check to make sure that the main gas
supply line to the range has been shut off,
(see below), and that the power supply
cord is disconnected from the AC outlet.
Gas Supply To Range

L.P. GAS CONVERSION

Fire Hazard
Gas Valve Handle
To "Shutoff" Position
Gas Supply Line
2.
To convert the cooktop burners for use
with L.P. gas:
a) Remove the grates and burner caps.
b) Remove the two T-20 torx screws from
each of the burner heads and remove
the heads from the cooktop.
Burner Head
NOTE: The L.P. orifices are fastened to the
back of the range near the bottom on a card-
board form.
Continued on the next page.
2-1
Orifice
Card

Hide quick links: