4.
Rear Assembly U
(Time required: About 9 minutes)
4-1.
Remove the SP1000. (See procedure 1.)
4-2.
Remove the MB1000. (See procedure 2.)
4-3.
Fasten the control panel assembly. (See procedure 3.)
4-4.
Remove the six (6) screws marked [40A] and the
two (2) screws marked [70A]. Fasten the rear
assembly U by the stay. (Fig.2, Photo.3-2)
4-5.
Remove the two (2) screws marked [40B]. The rear
assembly U can then be removed. (Fig.2)
Photo.3-1
<Left side view>
[70A]
[40B]
Side panel L
[40]: Bind Head Tapping Screw-B
[60A]: Bind Head Tapping Screw-B
[70A]: Bind Head Tapping Screw-B
Control panel assembly
Stay
(WA963600)
Bottom assembly
<Front view>
<Top view>
[40A]
[60A]
<Rear view>
[60A]
Fig.2
Photo.3-2
[60A]
[40A]
[60A]
Control panel assembly
[60A]
Rear assembly U
Bottom assembly
[40A]
4.0X8 MFZN2BL (EG340190)
4.0X8 MFZN2BL (EG340190)
3.0X6 MFZN2BL (EP600230)
DM1000/MB1000/SP1000
Control panel assembly
Rear assembly U
Stay
(WA963600)
Bottom assembly
<Right side view>
[70A]
[40B]
Side panel R