DM1000/MB1000/SP1000
Example of execution screen
Display for other
than Joystick

1-31. METER LED test

Contents:
Visually check that the 7-segment LEDs
and MB1000 LEDs light in the specified
order.
Example of execution screen
--- METER LED ---
OK
1 Channel Bargraph
NG 2 Time Code
NG 3 Others
[ENTER] key to Start
OK
NG
EXIT ([DEC] Key->[ENTER] Key)
The lighting orders are as follows:
1) Channel bar graph lighting
(LED lighting order: CH1 Lower → Upper.. CH 16
Lower → Upper, OUT BUS 1 Lower → Upper..OUT
BUS 8 Lower → Upper)
2) TIME CODE lighting (repeatedly)
H10 → H1 → M10 → M1 → S10 → S1 → F10 → F1
(Lighting order: 0 → 1..9 →. [dot])
3) Other lighting
(INPUT PRE EQ → PRE FADER → POST FADER
→ OUTPUT PRE EQ → PRE FADER → POST
FADER → CH 1-16_L → CH 17-32_L → CH 33-
48_L → AUX/BUS 1-8_L → CH 1-16_M → CH 17-
32_M → CH 33-48_M → AUX/BUS 1-8_M → CH
1-16_R → CH 17-32_R → CH 33-48_R → AUX/
BUS 1-8_R → 1-16 SW → 17-32 SW → 33-48 SW
→ PEAK HOLD SW → REMOTE 1 SW → REMOTE
2 SW → MASTER SW)
120

1-32. METER SW test

If the judgment is OK or NG,
the test continues with the check
of the next channel automatically.
If the Encoder does not operate,
etc., and the next channel is not
checked automatically, press the
[DEC] key. The channel becomes
NG and the test checks the next
channel.
Display for Joystick
L—>—R indicates left to
right Joystick movement.
L—<—R indicates right to
left Joystick movement.
D—>—U indicates down
to up Joystick movement.
D—<—U indicates up to
down Joystick movement.
Example of execution screen

1-98. MESSAGE LOG

Example of execution screen
Contents:
Check that the corresponding LEDs light/
turn off when the MB1000 SWs are
pressed.
The SWs and the corresponding LEDs are as follows:
Switch
1-16
1-16 light/turn off
17-32
17-32 light/turn off
33-48
33-48 LED light/turn off
PEAK HOLD
PEAK HOLD LED lights/turns off
REMOTE1
REMOTE 1 LED lights/turns off
REMOTE2
REMOTE 2 LED lights/turns off
MASTER
MASTER LED lights/turns off
Contents:
The log of the check results is displayed.
--- MESSAGE LOG ---
[ 2 BATT]
NG:BATT (2.56V)
[ 6 MIDI]
OK: SCI2
BACK:[UP]
NEXT:[DOWN]
EXIT:[ENTER]
Press the [ ] key to display the next page and press the
[ ] key to display the previous page.
Press the [ENTER] key to exit this page.
A maximum of 999 pages can be displayed in the log of
the check results. Any additional pages will not be
displayed.
To clear the log, end the Service Check Program or press
the [CLEAR] key of the SOLO.
LED
NG lines are displayed
in reverse.
Page
2

Hide quick links: