Enter Configuration
Ì$+;Î
3
Since you can concatenate codes from different families, you must select the Code ID character of the resulting code. The Code ID
character will be sent in the output message only if it is enabled according to the Code Identifier selection (Datalogic, AIM, or Custom).
4
Define the timeout, which determines the valid waiting period between the two codes, in order to accept concatenation. If the timeout
expires, the resulting action will be based on the following selection. (HHDII)
5
Product Reference Guide
ADVANCED FORMATTING
Concatenation Result Code ID
use code 1 ID
ÌEN0kÎ
use code 2 ID
ÌEN1nÎ
Concatenation Timeout
timeout
ÌEJ3Î
Read two numbers in the range 00 to 99
00= no timeout
01-99 = timeout from 1 to 99 seconds
Transmission after Timeout
no code transmitted
after timeout
ÌEM0iÎ
only code 1 transmitted
(if read) after timeout
ÌEM1lÎ
only code 2 transmitted
(if read) after timeout
ÌEM2oÎ
either code 1 or code 2 transmitted
after timeout
ÌEM3rÎ
Exit and Save Configuration