General Safety Instructions And Explanation Of Symbols; Explanation Of Symbols; Safety Instructions - Buderus LOGANO PLUS GB312 Installation Instructions Manual

Gas condensing boiler
Table of Contents

Advertisement

1

General safety instructions and explanation of symbols

1
General safety instructions and explanation
of symbols
1.1

Explanation of symbols

Warnings
Warnings in this document are framed
and identified by a warning triangle printed against a
grey background.
If there is a danger due to electricity, the exclamation
mark in the warning triangle is replaced by a lightning
symbol.
Keywords at the start of a warning indicate the type and seriousness of
the ensuing risk if measures to prevent the risk are not taken.
• NOTE indicates that material losses may occur.
• CAUTION indicates that minor to medium injury
may occur.
• WARNING indicates that severe injury may occur.
• DANGER indicates a risk to life.
Important information
Important information where there is no risk to people or
property is indicated with the adjacent symbol. It is
bordered by lines above and below the text.
Additional symbols
Symbol
Explanation
Action step
Cross-reference to other parts of this document or to
other documents
List/list entry
List/list entry (level 2)
4
1.2

Safety instructions

If you smell gas
▶ Turn off the gas cock ( page 40).
▶ Open doors and windows.
▶ Do not operate any electrical switches or equipment such as
telephones, power plugs and doorbells.
▶ Extinguish all open flames. Do not smoke. Do not use lighters.
▶ Warn all occupants of the building, but do not ring doorbells.
▶ If you can actually hear gas escaping, leave the building immediately.
Prevent others from entering and notify the police and fire
department from outside the building.
▶ From outside the building, call your gas supply utility and approved
contractor.
If you smell flue gas
▶ Switch "off" the boiler ( page 40).
▶ Open doors and windows.
▶ Inform an authorized heating contractor.
Danger of poisoning. Insufficient ventilation may cause dangerous
flue gas leaks.
▶ Never close off or reduce the size of air intake and outlet openings.
▶ The boiler must not be operated until the obstruction has been
removed.
▶ Inform the system user in writing of the problem and associated
danger.
Danger of explosion of flammable gases.
▶ Any work on components that carry gas or oil may only be carried out
by a certified heating contractor.
Dangers posed by explosive and easily combustible materials
▶ Do not use or store easily-combustible materials (paper, lace
curtains, clothing, thinners, paints, etc.) near the boiler.
▶ Maintain a clearance of 16 inches from the boiler.
Combustion air
▶ Keep the combustion air free of corrosive substances (e. g.
halogenated hydrocarbons that contain chlorine or fluorine
compounds). This will help prevent corrosion.
Danger of escaping flue gases
▶ Make sure that the vent pipes and gaskets are not damaged.
▶ Use high temperature silicon as sealing compound.
▶ The boiler must not be fitted with a barometric damper or a thermally
controlled flue flap downstream of the flue socket.
▶ Connect only one boiler to each flue system or chimney flue.
▶ Connection of another boiler may cause serious injury or death.
▶ The flue system pipes must not feed into another air extraction duct.
▶ Do not route the flue system piping through or inside another air
extraction duct, for example where there is a masonry or
prefabricated chimney flue.
Danger from electric current when the boiler is open
▶ Before opening the boiler: Disconnect the heating system from the
electrical power supply by means of the emergency stop switch or the
relevant circuit breaker on the main fuse board.
▶ It is not sufficient just to switch off the control unit.
▶ Take measures to ensure that the heating system cannot be switched
on again unintentionally.
Logano plus GB312 – 6 720 647 367 (2012/11)